Libraries
.
LargeTestSuite
.
Thermal
.
HeatExchanger
.
CocurrentHeatExchangerEquations_N_81920
OMC
latest
demo
☼
model
CocurrentHeatExchangerEquations_N_81920
▶ Simulate in your browser
Extends from
CocurrentHeatExchangerEquations_N_1280
.
Parameters
Type
Name
Default
Description
SIunits.Length
L
(from CocurrentHeatExchangerEquations)
length of the channels
Integer
N
(from CocurrentHeatExchangerEquations)
2
number of nodes
SIunits.MassFlowRate
wB
(from CocurrentHeatExchangerEquations)
mass flow rate of fluid B
SIunits.Area
areaA
(from CocurrentHeatExchangerEquations)
cross sectional area of channel A
SIunits.Area
areaB
(from CocurrentHeatExchangerEquations)
cross sectional area of channel B
SIunits.Density
rhoA
(from CocurrentHeatExchangerEquations)
density of fluid A
SIunits.Density
rhoB
(from CocurrentHeatExchangerEquations)
density of fluid B
SIunits.SpecificHeatCapacity
cpA
(from CocurrentHeatExchangerEquations)
specific heat capacity of fluid A
SIunits.SpecificHeatCapacity
cpB
(from CocurrentHeatExchangerEquations)
specific heat capacity of fluid B
SIunits.SpecificHeatCapacity
cpW
(from CocurrentHeatExchangerEquations)
specific heat capacity of the wall
SIunits.CoefficientOfHeatTransfer
gammaA
(from CocurrentHeatExchangerEquations)
heat transfer coefficient of fluid A
SIunits.CoefficientOfHeatTransfer
gammaB
(from CocurrentHeatExchangerEquations)
heat transfer coefficient of fluid B
SIunits.Length
omega
(from CocurrentHeatExchangerEquations)
perimeter
SIunits.Length
l
(from CocurrentHeatExchangerEquations)
L/(N - 1)
length of the each wall segment
Components
Type
Name
Default
Description
SIunits.MassFlowRate
wA
(from CocurrentHeatExchangerEquations)
mass flow rate of fluid A
SIunits.HeatFlowRate
[N - 1]
QA
(from CocurrentHeatExchangerEquations)
heat flow rate of fluid A in the segments
SIunits.HeatFlowRate
[N - 1]
QB
(from CocurrentHeatExchangerEquations)
heat flow rate of fluid B in the segments
SIunits.Temperature
[N]
TA
(from CocurrentHeatExchangerEquations)
temperature nodes on channel A
SIunits.Temperature
[N]
TB
(from CocurrentHeatExchangerEquations)
temperature nodes on channel B
SIunits.Temperature
[N - 1]
TAtilde
(from CocurrentHeatExchangerEquations)
temperature states on channel A
SIunits.Temperature
[N - 1]
TBtilde
(from CocurrentHeatExchangerEquations)
temperature states on channel B
SIunits.Temperature
[N - 1]
TW
(from CocurrentHeatExchangerEquations)
temperatures on the wall segments
SIunits.HeatFlowRate
QtotA
(from CocurrentHeatExchangerEquations)
total heat flow rate of fluid A
SIunits.HeatFlowRate
QtotB
(from CocurrentHeatExchangerEquations)
total heat flow rate of fluid B