modelTurbineWithWasteGate

Turbine with Wastegate

Extends from Basic.Restrictions.Partial.TwoPort (Model for all Flow Components with InPut and OutPut ).

Parameters

TypeNameDefaultDescription
SI.AreaWG_Amax3.5e-4Maximum Wastegate Area
RealWG_Cd0.9Discharge coefficient (Flow efficiency)
Realk10.0170Turbine mass flow fit parameter
Realk21.4Turbine mass flow fit parameter
SI.LengthD0.05Trubine diameter
SI.Efficiencyeta_max0.75Maximum efficiency
Realeta_max_BSR0.7Maximum efficiency blade speed ratio
SI.Efficiencyeta_min0.3Minimum efficiency

Connectors

TypeNameDefaultDescription
Interfaces.GasPortInPut (from TwoPort)
Interfaces.GasPortOutPut (from TwoPort)
Modelica.Blocks.Interfaces.RealInputuWG
Modelica.Mechanics.Rotational.Interfaces.Flange_aflange_a

Components

TypeNameDefaultDescription
FixedTurbinefixedTurbine
Basic.Restrictions.Compressiblecompressible
Modelica.Blocks.Math.GainuWGtoArea