| Real | V_nom | 24e3 | Nominal phase-to-phase RMS voltage |
| Real | P_nom | 555e6 | Nominal turbine (active) power (MW) |
| Real | f_nom | 60 | Nominal frequency |
| Real | p | 1 | Number of pole pairs |
| Real | H | 3.7 | Inertia constant |
| Real | R_s | 0.003 | Stator Resistance |
| Real | L_l | 0.15 | Stator leakage |
| Real | L_md | 1.6599 | d axis mutual inductance |
| Real | L_mq | 1.61 | q axis mutual inductance |
| Real | R_fd | 0.0006 | Rotor Resistance |
| Real | L_lfd | 0.1648 | Rotor leakage |
| Real | theta_volt_init | -Modelica.Constants.pi/2 | initial voltage angle |
| Real | vt_init | sqrt(2/3)*V_nom/v_b | |
| Real | omega_nom | 2*Modelica.Constants.pi*f_nom | Nominal angular frequency |
| Real | v_b | sqrt(2/3)*V_nom | |
| Real | i_b | 2/3*P_nom/v_b | |
| Real | omega_b | omega_nom/p | |