A single cell depleted to SOC = 0.1
is recharged with a CC-CV charger.
Charging current in CC mode is 5C which means the battery is theoretically nearly fulled charged after 0.9*3600 s/5 = 648 s
and the charger switches to CV mode.
Simulate for 1200 s and plot cell.cellBus.soc
versus time
.