Model of a DC Machine with electrical shunt or separate excitation.
Armature resistance and inductance are modeled directly after the armature pins, then using a AirGapDC model.
The machine models take the following loss effects into account:

No saturation is modelled.
Shunt or separate excitation is defined by the user's external circuit.
Default values for machine's parameters (a realistic example) are:

stator's moment of inertia 0.29kg.m2
rotor's moment of inertia 0.15kg.m2
nominal armature voltage 100V
nominal armature current 100A
nominal torque 63.66Nm
nominal speed 1425rpm
nominal mechanical output 9.5kW
efficiency 95.0% only armature
efficiency 94.06% including excitation
armature resistance 0.05Ohm at reference temperature
reference temperature TaRef 20°C
temperature coefficient alpha20a 01/K
armature inductance 0.0015H
nominal excitation voltage 100V
nominal excitation current 1A
excitation resistance 100Ohm at reference temperature
reference temperature TeRef 20°C
temperature coefficient alpha20e 01/K
excitation inductance 1H
stray part of excitation inductance 0
armature nominal temperature TaNominal 20°C
armature operational temperature TaOperational 20°C
(shunt) excitation operational temperature TeOperational 20°C
Armature resistance resp. inductance include resistance resp. inductance of commutating pole winding and compensation winding, if present.
Armature current does not cover excitation current of a shunt excitation; in this case total current drawn from the grid = armature current + excitation current.