.Modelica.Electrical.Machines.Examples.DCMachines.DCPM_Temperature

Information

Test example: Investigate influence of armature temperature on a DCPM motor
The motor starts at no-load speed, then a load step is applied.
Beginning with the load step, the armature temperature rises exponentially from 20 degC to 80 degC.
Simulate for 3 seconds and plot (versus time): Default machine parameters are used, but: So the machine is at the beginning in cold condition, ending in warm condition (with the same armature resistance as the unmodified machine).
Generated at 2025-02-05T19:26:06Z by OpenModelicaOpenModelica 1.24.4 using GenerateDoc.mos