Test example: Investigate influence of armature temperature on a DCPM motor
The motor starts at no-load speed, then a load step is applied.
Beginning with the load step, the armature temperature rises exponentially from 20 degC to 80 degC.
Simulate for 3 seconds and plot (versus time):
- dcpm.ia: armature current
- dcpm.wMechanical: motor's speed
- dcpm.tauElectrical: motor's torque
- thermalAmbientDCPM.Q_flow_a: motor's armature losses
Default machine parameters are used, but:
- The armature winding material is set to Copper.
- Armature reference temperature is set to 80 degC.
- Nominal armature temperature is set to 80 degC.
So the machine is at the beginning in cold condition, ending in warm condition
(with the same armature resistance as the unmodified machine).
Generated at 2025-02-05T19:26:06Z
by OpenModelicaOpenModelica 1.24.4 using GenerateDoc.mos