.Modelica.Electrical.Machines.Examples.InductionMachines.IMC_DCBraking

Information

The stator windings of an induction machine are fed by a DC current, causing a stationary current space phasor. Since the rotor is turning, voltage is induced in the rotor cage which in turn drives rotor currents. This creates a braking torque.

Choose a layout and plot tauElectrical and tauShaft versus wMechanical.

Default machine parameters are used.

References

[Fischer2017] R. Fischer, Elektrische Maschinen, 17th ed., chapter 5.3.3., Hanser, ISBN 978-3-446-45218-3, 2017.