Test example: SynchronousMachineReluctanceRotor with inverter
An ideal frequency inverter is modeled by using a VfController
and a three-phase SignalVoltage. Frequency is raised by a ramp,
causing the reluctance machine to start, and accelerating inertias.
At time tStep a load step is applied.
Simulate for 1.5 seconds and plot (versus time):
- currentQuasiRMSSensor.I: stator current RMS
- smr.wMechanical: motor's speed
- smr.tauElectrical: motor's torque
- rotorDisplacementAngle.rotorDisplacementAngle: rotor
displacement angle
Default machine parameters are used.
Generated at 2026-05-04T18:18:56Z by OpenModelicaOpenModelica 1.26.7 using
GenerateDoc.mos