Transformer test bench:
You may choose different connections as well as vary the load (even not symmetrical).
Please pay attention to proper grounding of the primary and secondary part of the whole circuit.
The primary and secondary starpoint are available as connectors, if the connection is not delta (D or d).
In some cases it may be necessary to ground the transformer's starpoint
even though the source's or load's starpoint are grounded; you may use a reasonable high earthing resistance.
Generated at 2024-12-11T19:25:49Z
by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos