.Modelica.Fluid.Dissipation.HeatTransfer.Channel.kc_evenGapTurbulent

Information

Calculation of the mean convective heat transfer coefficient kc for a developed turbulent fluid flow through an even gap at heat transfer from both sides. Note that additionally a failure status is observed in this function to check if the intended boundary conditions are fulfilled. See more information.

Interface

function kc_evenGapTurbulent
  extends Modelica.Icons.Function;
  import MIN = Modelica.Constants.eps;
  input Modelica.Fluid.Dissipation.HeatTransfer.Channel.kc_evenGapTurbulent_IN_con IN_con "Input record for function kc_evenGapTurbulent" annotation(
    Dialog(group = "Constant inputs"));
  input Modelica.Fluid.Dissipation.HeatTransfer.Channel.kc_evenGapTurbulent_IN_var IN_var "Input record for function kc_evenGapTurbulent" annotation(
    Dialog(group = "Variable inputs"));
  output SI.CoefficientOfHeatTransfer kc "Convective heat transfer coefficient" annotation(
    Dialog(group = "Output"));
  output SI.PrandtlNumber Pr "Prandtl number" annotation(
    Dialog(group = "Output"));
  output SI.ReynoldsNumber Re "Reynolds number" annotation(
    Dialog(group = "Output"));
  output SI.NusseltNumber Nu "Nusselt number" annotation(
    Dialog(group = "Output"));
  output Real failureStatus "0== boundary conditions fulfilled | 1== failure >> check if still meaningful results" annotation(
    Dialog(group = "Output"));
end kc_evenGapTurbulent;

Generated at 2024-11-26T19:26:15Z by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos