.Modelica.Fluid.Pipes.BaseClasses.FlowModels.PartialStaggeredFlowModel

Information

This partial model defines a common interface for m=n-1 flow models between n device segments. The flow models provide a steady-state or dynamic momentum balance using an upwind discretization scheme per default. Extending models must add pressure loss terms for friction and gravity.

The fluid is specified in the interface with the thermodynamic states[n] for a given Medium model. The geometry is specified with the pathLengths[n-1] between the device segments as well as with the crossAreas[n] and the roughnesses[n] of the device segments. Moreover the fluid flow is characterized for different types of devices by the characteristic dimensions[n] and the average velocities vs[n] of fluid flow in the device segments. See Pipes.BaseClasses.CharacteristicNumbers.ReynoldsNumber for example definitions.

The parameter Re_turbulent can be specified for the least mass flow rate of the turbulent regime. It defaults to 4000, which is appropriate for pipe flow. The m_flows_turbulent[n-1] resulting from Re_turbulent can optionally be calculated together with the Reynolds numbers Res[n] of the device segments (show_Res=true).

Using the thermodynamic states[n] of the device segments, the densities rhos[n] and the dynamic viscosities mus[n] of the segments as well as the actual densities rhos_act[n-1] and the actual viscosities mus_act[n-1] of the flows are predefined in this base model. Note that no events are raised on flow reversal. This needs to be treated by an extending model, e.g., with numerical smoothing or by raising events as appropriate.

Contents

NameDescription
 MediumMedium in the component