This model compares a transient-linear magnetic circuit with a quasi-static magnetic circuit. A sinusoidal voltage is applied to an inductor with a closed ferromagnetic core of rectangular shape.
Compare the following quantities
- Sinusoidal supply voltage
source.v | sourceQS.v.re|im
- Non-linear transient current due to saturation and equivalent quasi-static current
currentSensor.i | currentSensorQS.i.re|im
- Difference between RMS fundamental wave of transient current and the RMS quasi-static current
feedback.y
- Relative permeability of iron core of transient and quasi-static circuit
r_mFe.mu_rConst | r_mFeQS.mu_rConst
Generated at 2024-11-23T19:25:52Z