Permanent magnet losses are modeled dependent on current and speed.
The permanent magnet losses are modeled such way that they do not cause a voltage drop in the electric circuit. Instead, the dissipated losses are considered through an equivalent braking torque at the shaft.
The permanent magnet loss torque is
tau = PRef/wRef * (c + (1 - c) * (i/IRef)^power_I) * (w/wRef)^power_w
where i
is the current of the machine and w
is the actual angular velocity.
The parameter c
designates the part of the permanent magnet losses that are present even at current = 0, i.e. independent of current.
The dependency of the permanent magnet loss torque on the stator current is modeled by the exponent power_I
.
The dependency of the permanent magnet loss torque on the angular velocity is modeled by the exponent power_w
.
Permanent magnet loss parameters
If it is desired to neglect permanent magnet losses, set strayLoadParameters.PRef = 0
(this is the default).