modelCCCV_CellRC

Charge a transient cell with constant current - constant voltage characteristic

Extends from Modelica.Icons.Example (Icon for runnable examples).

Information

A single transient cell depleted to SOC = 0.1 is recharged with a CC-CV charger. Charging current in CC mode is 5C which means the battery is theoretically nearly fulled charged after 0.9*3600 s/5 = 648 s and the charger switches to CV mode. Simulate for 1200 s and plot cell.cellBus.soc versus time.

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.CurrentIsc1200Short-circuit current of cell at OCVmax
Modelica.Electrical.Batteries.ParameterRecords.TransientData.ExampleDatacellDataCell data

Components

TypeNameDefaultDescription
Modelica.Electrical.Batteries.Utilities.CCCVchargercccvCharger
Modelica.Electrical.Analog.Basic.Groundground
Modelica.Electrical.Batteries.BatteryStacksWithSensors.CellRCcell
Analog.Sensors.MultiSensormultiSensor
Blocks.Continuous.Integratorenergy