blockLogicToUX01

Conversion to UX01

Information

Conversion of a nine valued digital input into a UX01 digital output without any delay according to IEEE 1164 To_UX01 function.

Conversion Table:

input                  output
'U' (coded by 1)       'U'  (coded by 1)
'X' (coded by 2)       'X'  (coded by 2)
'0' (coded by 3)       '0'  (coded by 3)
'1' (coded by 4)       '1'  (coded by 4)
'Z' (coded by 5)       'X'  (coded by 2)
'W' (coded by 6)       'X'  (coded by 2)
'L' (coded by 7)       '0'  (coded by 3)
'H' (coded by 8)       '1'  (coded by 4)
'-' (coded by 9)       'X'  (coded by 2)

If the signal width is greater than 1 this conversion is done for each signal.

Parameters

TypeNameDefaultDescription
IntegernSignal width

Connectors

TypeNameDefaultDescription
D.Interfaces.DigitalInput[n]x
D.Interfaces.DigitalOutput[n]y

Revisions

  • September 15, 2004 by Christoph Clauss name converted from cvt_to_ux01 into LogicToUX01
  • November 5, 2003 by Christoph Clauss
    initially modelled.