blockSet

Digital Set Source

Information

Sets a nine valued digital signal, which is specified by the setval parameter.

To specify setval, the integer code has to be used.

Code Table

Logic value Integer code Meaning
'U' 1 Uninitialized
'X' 2 Forcing Unknown
'0' 3 Forcing 0
'1' 4 Forcing 1
'Z' 5 High Impedance
'W' 6 Weak Unknown
'L' 7 Weak 0
'H' 8 Weak 1
'-' 9 Do not care

If the logic values are imported by
import L = Digital.Interfaces.Logic;
they can be used to specify the parameter, e.g., L.'0' for forcing 0.

Parameters

TypeNameDefaultDescription
D.Interfaces.LogicxLogic value to be set

Connectors

TypeNameDefaultDescription
D.Interfaces.DigitalOutputy

Revisions

August 20, 2003
by Teresa Schlegel initially modelled.