packageSynchronousMachines
Models of synchronous machines
Extends from Modelica.Icons.VariantsPackage (Icon for package containing variants).
Information
This package contains models of synchronous machines, based on space phasor theory:- SM_PermanentMagnet: synchronous machine with permanent magnet excitation, with damper cage
- SM_ElectricalExcited: synchronous machine with electrical excitation and damper cage
- SM_ReluctanceRotor: induction machine with reluctance rotor and damper cage
i.e., a squirrel cage rotor with magnetic poles due to different airgap width
Please keep in mind:
- We keep the same reference system as for motors, i.e.:
Positive RotorDisplacementAngle means acting as motor,
with positive electric power consumption and positive mechanical power output. - ElectricalAngle = p * MechanicalAngle
- real axis = d-axis
imaginary= q-axis - Voltage induced by the magnet wheel (d-axis) is located in the q-axis.
Contents
| Name | Description |
|---|---|
| Permanent magnet synchronous machine | |
| Electrical excited synchronous machine with damper cage | |
| Synchronous machine with reluctance rotor and damper cage |
Revisions
- Main Authors:
-
Anton Haumer
Technical Consulting & Electrical Engineering
D-93049 Regensburg
Germany
email: a.haumer@haumer.at
- v1.02 2004/09/19 Anton Haumer
- v1.03 2004/09/24 Anton Haumer
consistent naming of inductors and resistors in machine models - v1.1 2004/10/01 Anton Haumer
changed naming and structure
issued to Modelica Standard Library 2.1 - v1.2 2004/10/27 Anton Haumer
fixed a bug with support (formerly bearing) - v1.3.2 2004/11/10 Anton Haumer
ReluctanceRotor moved to SynchronousMachines - v1.4 2004/11/11 Anton Haumer
removed mechanical flange support
to ease the implementation of a 3D-frame in a future release - v1.52 2005/10/12 Anton Haumer
added SM_ElectricalExcited - v1.53 2005/10/14 Anton Haumer
introduced unsymmetrical DamperCage for Synchronous Machines - v1.6.2 2005/10/23 Anton Haumer
selectable DamperCage for Synchronous Machines - v1.7.1 2006/02/06 Anton Haumer
changed some naming of synchronous machines, not affecting existing models - v2.2.0 2011/02/10 Anton Haumer
conditional ThermalPort for all machines