modelIMC_Transformer

Test example: InductionMachineSquirrelCage transformer starting

Extends from Machines.Examples.InductionMachines.IMC_Transformer (Test example: InductionMachineSquirrelCage transformer starting).

Information

Test example: Induction machine with squirrel cage - transformer starting
At start time tStart1 three-phase voltage is supplied to the induction machine with squirrel cage via the transformer; the machine starts from standstill, accelerating inertias against load torque quadratic dependent on speed; at start time tStart2 the machine is fed directly from the voltage source, finally reaching nominal speed.
Simulate for 2.5 seconds and plot (versus time):
  • currentQuasiRMSSensor.I: stator current RMS
  • aimc.wMechanical: motor's speed
  • aimc.tauElectrical: motor's torque
Default machine parameters of model IM_SquirrelCage are used.

Parameters

TypeNameDefaultDescription
Integerm (from IMC_Transformer)3Number of phases
SI.VoltageVNominal (from IMC_Transformer)100Nominal RMS voltage per phase
SI.FrequencyfNominal (from IMC_Transformer)50Nominal frequency
SI.TimetStart1 (from IMC_Transformer)0.1Start time
SI.TimetStart2 (from IMC_Transformer)2.0Start time of bypass transformer
SI.TorqueTLoad (from IMC_Transformer)161.4Nominal load torque
SI.AngularVelocitywLoad (from IMC_Transformer)1440.45*2*Modelica.Constants.pi/60Nominal load speed
SI.InertiaJLoad (from IMC_Transformer)0.29Load's moment of inertia
Machines.Utilities.TransformerDatatransformerData (from IMC_Transformer)Transformer data
Utilities.ParameterRecords.IM_SquirrelCageDataaimcData (from IMC_Transformer)Induction machine data

Components

TypeNameDefaultDescription
Machines.BasicMachines.InductionMachines.IM_SquirrelCageaimc (from IMC_Transformer)
Machines.Sensors.CurrentQuasiRMSSensorcurrentQuasiRMSSensor (from IMC_Transformer)
Modelica.Electrical.Polyphase.Sources.SineVoltagesineVoltage (from IMC_Transformer)
Modelica.Electrical.Polyphase.Basic.Starstar (from IMC_Transformer)
Modelica.Electrical.Analog.Basic.Groundground (from IMC_Transformer)
Modelica.Blocks.Sources.BooleanStep[m]booleanStep1 (from IMC_Transformer)
Modelica.Electrical.Polyphase.Ideal.IdealClosingSwitchidealCloser (from IMC_Transformer)
Machines.BasicMachines.Transformers.Yy.Yy00transformer (from IMC_Transformer)
Modelica.Electrical.Analog.Basic.Groundground2 (from IMC_Transformer)
Modelica.Blocks.Sources.BooleanStep[m]booleanStep2 (from IMC_Transformer)
Modelica.Electrical.Polyphase.Ideal.IdealCommutingSwitchidealCommutingSwitch (from IMC_Transformer)
Modelica.Mechanics.Rotational.Components.InertialoadInertia (from IMC_Transformer)
Modelica.Mechanics.Rotational.Sources.QuadraticSpeedDependentTorquequadraticLoadTorque (from IMC_Transformer)
Machines.Utilities.TerminalBoxterminalBox (from IMC_Transformer)