recordSM_ElectricalExcitedData

Common parameters for synchronous machines with electrical excitation

Extends from SM_ReluctanceRotorData (Common parameters for synchronous machines with reluctance rotor).

Information

Basic parameters of synchronous machines with electrical excitation are predefined with default values.

Parameters

TypeNameDefaultDescription
Integerm (from InductionMachineData)3Number of phases
SI.InertiaJr (from InductionMachineData)0.29Rotor's moment of inertia
SI.InertiaJs (from InductionMachineData)JrStator's moment of inertia
Integerp (from InductionMachineData)2Number of pole pairs (Integer)
SI.FrequencyfsNominal (from InductionMachineData)50Nominal frequency
RealeffectiveStatorTurns (from InductionMachineData)1Effective number of stator turns
Nominal resistances and inductances
SI.ResistanceRs (from InductionMachineData)0.03Stator resistance per phase at TRef
SI.TemperatureTsRef (from InductionMachineData)293.15Reference temperature of stator resistance
Machines.Thermal.LinearTemperatureCoefficient20alpha20s (from InductionMachineData)0Temperature coefficient of stator resistance at 20 degC
SI.InductanceLszero (from InductionMachineData)LssigmaStator zero sequence inductance
SI.InductanceLssigma (from InductionMachineData)3*(1 - sqrt(1 - 0.0667))/(2*pi*fsNominal)Stator stray inductance per phase
RealratioCommonStatorLeakage (from InductionMachineData)1Ratio of common stray inductance / total stray inductance of stator winding
SI.InductanceLmd (from SM_ReluctanceRotorData)2.9/(2*pi*fsNominal)Stator main field inductance per phase in d-axis
SI.InductanceLmq (from SM_ReluctanceRotorData)0.9/(2*pi*fsNominal)Stator main field inductance per phase in q-axis
Losses
Machines.Losses.FrictionParametersfrictionParameters (from InductionMachineData)Friction loss parameter record
Machines.Losses.CoreParametersstatorCoreParameters (from InductionMachineData)Stator core loss parameter record; all parameters refer to stator side
Machines.Losses.StrayLoadParametersstrayLoadParameters (from InductionMachineData)Stray load losses
Machines.Losses.BrushParametersbrushParametersBrush loss parameter record
Nominal resistances and inductances › Damper cage
BooleanuseDamperCage (from SM_ReluctanceRotorData)trueEnable / disable damper cage
SI.InductanceLrsigmad (from SM_ReluctanceRotorData)0.05/(2*pi*fsNominal)Damper stray inductance in d-axis
SI.InductanceLrsigmaq (from SM_ReluctanceRotorData)LrsigmadDamper stray inductance in q-axis
SI.ResistanceRrd (from SM_ReluctanceRotorData)0.04Damper resistance in d-axis at TRef
SI.ResistanceRrq (from SM_ReluctanceRotorData)RrdDamper resistance in q-axis at TRef
SI.TemperatureTrRef (from SM_ReluctanceRotorData)293.15Reference temperature of damper resistances in d- and q-axis
Machines.Thermal.LinearTemperatureCoefficient20alpha20r (from SM_ReluctanceRotorData)0Temperature coefficient of damper resistances in d- and q-axis
Excitation
SI.VoltageVsNominal100Nominal stator RMS voltage per phase
SI.CurrentIeOpenCircuit10Open circuit excitation current @ nominal voltage and frequency
SI.ResistanceRe2.5Excitation resistance at TRef
SI.TemperatureTeRef293.15Reference temperature of excitation resistance
Machines.Thermal.LinearTemperatureCoefficient20alpha20e0Temperature coefficient of excitation resistance
Realsigmae0.025Stray fraction of total excitation inductance