modelSwitchYDwithArc

Y-D-switch with arc

Information

Star-Delta-switch with arc when switch opens.
If control is false, plug_sp and plug_sn are star connected and plug_sp connected to the supply plug.
If control is true, plug_sp and plug_sn are delta connected and they are connected to the supply plug.
Note there is a delay between opening star connection and closing delta connection, respectively opening delta connection and closing star connection.

Parameters

TypeNameDefaultDescription
Integerm3Number of phases
SI.ResistanceRon1e-5Closed switch resistance
SI.ConductanceGoff1e-5Opened switch conductance
SI.TimedelayTime0Time delay
SI.VoltageV0Initial arc voltage
SI.VoltageSlopedVdtArc voltage slope
SI.VoltageVmaxMax. arc voltage

Connectors

TypeNameDefaultDescription
Modelica.Electrical.Polyphase.Interfaces.PositivePlugplugSupplyTo grid
Modelica.Electrical.Polyphase.Interfaces.PositivePlugplug_spTo positive stator plug
Modelica.Electrical.Polyphase.Interfaces.NegativePlugplug_snTo negative stator plug
Modelica.Blocks.Interfaces.BooleanInput[m]control

Components

TypeNameDefaultDescription
Modelica.Electrical.Polyphase.Basic.Starstar
Modelica.Electrical.Polyphase.Basic.Deltadelta
Polyphase.Ideal.CloserWithArcidealCloser
Polyphase.Ideal.OpenerWithArcidealOpener
Blocks.Logical.LogicalDelay[m]logicalDelay