modelSwitchedRheostat

Rheostat which is shortened after a given time

Information

Switched rheostat, used for starting induction motors with slipring rotor:

The external rotor resistance RStart is shortened at time tStart.

Parameters

TypeNameDefaultDescription
Integerm3Number of phases
SI.ResistanceRStartStarting resistance
SI.TimetStartDuration of switching on the starting resistor

Connectors

TypeNameDefaultDescription
Modelica.Electrical.Polyphase.Interfaces.PositivePlugplug_pTo positive rotor plug
Modelica.Electrical.Polyphase.Interfaces.NegativePlugplug_nTo negative rotor plug

Components

TypeNameDefaultDescription
Modelica.Electrical.Polyphase.Basic.Starstar
Modelica.Electrical.Analog.Basic.Groundground
Modelica.Electrical.Polyphase.Ideal.IdealCommutingSwitchidealCommutingSwitch
Modelica.Electrical.Polyphase.Basic.Resistorrheostat
Modelica.Electrical.Polyphase.Basic.StarstarRheostat
Modelica.Blocks.Sources.BooleanStep[m]booleanStep