modelPolyphaseInitialization
Extends from Modelica.Icons.Example (Icon for runnable examples).
Information
Proper initialization of polyphase systems requires an analysis of the circuit, helping to decide
how many states and which states should be initialized with fixed=true (or fixed=false).
This example demonstrates the initialization of three-phase inductances in a 3 wire and a 4 wire system:
In the 3 wire system the implicit equation i11 + i12 + i13 = 0 has to be taken into account.
Therefore only 2 of the 3 currents may be initialized with fixed=true.
With the polyphase component, the initial values have to be set accordingly. e.g.:
Inductor inductor(m=3, iL(start={0, 0, 0}, fixed={true, true, false}));
In the 4 wire system the implicit equation i21 + i22 + i23 = i20 has to be taken into account.
Therefore all 3 currents may be initialized with fixed=true.
With the polyphase component, the initial values have to be set accordingly, e.g.:
Inductor inductor(m=3, iL(start={0, 0, 0}, fixed={true, true, true }));
It depends on the tool whether you have to set the fixed attribute textually, or if it is possible to do it graphically.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | m | 3 | Number of phases |
| SI.Voltage | V | 230 | RMS voltage line to neutral |
| SI.Frequency | f | 50 | Source frequency |
| SI.Impedance | Z | 10 | Total impedance |
| SI.Resistance | R | Z/sqrt(2) | Resistive component |
| SI.Inductance | L | Z/sqrt(2)/(2*pi*f) | Inductive component |