modelThyristor1Pulse_R_Characteristic
Control characteristic of one pulse rectifier with resistive load
Extends from ExampleTemplates.Thyristor1Pulse (Template of single pulse rectifier), Modelica.Icons.Example (Icon for runnable examples).
Information
This example demonstrates the operational behavior of a single-phase controlled rectifier with variable firing angle and resistive load. The average load voltage can be controlled by means of the firing angle.
Plot average voltage meanVoltage.v versus firingAngle pulse2.firingAngle to see control characteristic of this type of rectifier with resistive load.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Voltage | Vrms (from Thyristor1Pulse) | 110 | RMS supply voltage |
| SI.Frequency | f (from Thyristor1Pulse) | 50 | Frequency |
| SI.Resistance | R | 20 | Load resistance |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Electrical.Analog.Sensors.VoltageSensor | voltagesensor (from Thyristor1Pulse) | ||
| Modelica.Electrical.Analog.Sources.SineVoltage | sinevoltage (from Thyristor1Pulse) | ||
| Modelica.Electrical.Analog.Basic.Ground | ground (from Thyristor1Pulse) | ||
| Modelica.Electrical.Analog.Sensors.CurrentSensor | currentSensor (from Thyristor1Pulse) | ||
| Modelica.Blocks.Math.Mean | meanVoltage (from Thyristor1Pulse) | ||
| Modelica.Blocks.Math.RootMeanSquare | rootMeanSquareVoltage (from Thyristor1Pulse) | ||
| Modelica.Blocks.Math.Mean | meanCurrent (from Thyristor1Pulse) | ||
| PowerConverters.ACDC.Control.VoltageBridge2Pulse | pulse2 (from Thyristor1Pulse) | ||
| Modelica.Electrical.Analog.Ideal.IdealThyristor | idealthyristor (from Thyristor1Pulse) | ||
| Modelica.Electrical.Analog.Basic.Resistor | resistor | ||
| Modelica.Blocks.Sources.Ramp | ramp |