modelThyristorBridge2mPulse_RLV

2*m pulse thyristor rectifier bridge with R-L load and voltage

Extends from ExampleTemplates.ThyristorBridge2mPulse (Template of 2*m pulse bridge thyristor rectifier), Modelica.Icons.Example (Icon for runnable examples).

Information

This example shows a full controlled 2*m pulse bridge rectifier with R-L load including DC voltage source, where m is the number of phases. The additional DC voltage source in this example enables negative average load voltages.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Parameters

TypeNameDefaultDescription
Integerm (from ThyristorBridge2mPulse)3Number of phases
SI.VoltageVrms (from ThyristorBridge2mPulse)110RMS supply voltage
SI.Frequencyf (from ThyristorBridge2mPulse)50Frequency
SI.AngleconstantFiringAngle30*pi/180Firing angle
SI.ResistanceR20Load resistance
SI.InductanceL1Load resistance
SI.VoltageVDC-260DC load offset voltage

Components

TypeNameDefaultDescription
Modelica.Electrical.Polyphase.Sources.SineVoltagesineVoltage (from ThyristorBridge2mPulse)
PowerConverters.ACDC.ThyristorBridge2mPulserectifier (from ThyristorBridge2mPulse)
Modelica.Electrical.Analog.Sensors.VoltageSensorvoltagesensor (from ThyristorBridge2mPulse)
Modelica.Blocks.Math.MeanmeanVoltage (from ThyristorBridge2mPulse)
Modelica.Blocks.Math.RootMeanSquarerootMeanSquareVoltage (from ThyristorBridge2mPulse)
Modelica.Electrical.Analog.Sensors.CurrentSensorcurrentSensor (from ThyristorBridge2mPulse)
Modelica.Blocks.Math.MeanmeanCurrent (from ThyristorBridge2mPulse)
PowerConverters.ACDC.Control.VoltageBridge2mPulsepulse2m (from ThyristorBridge2mPulse)
Modelica.Electrical.Polyphase.Basic.MultiStarResistancemultiStarResistance (from ThyristorBridge2mPulse)
Modelica.Electrical.Analog.Basic.Groundground (from ThyristorBridge2mPulse)
Modelica.Electrical.Analog.Basic.Resistorresistor
Modelica.Electrical.Analog.Basic.Inductorinductor
Modelica.Electrical.Analog.Sources.ConstantVoltageconstantVoltage