modelThyristorCenterTap2Pulse_R

Two pulse thyristor rectifier with center tap and resistive load

Extends from ExampleTemplates.ThyristorCenterTap2Pulse (Template of two pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).

Information

This example shows a controlled center tap two pulse rectifier with resistive load.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Parameters

TypeNameDefaultDescription
SI.VoltageVrms (from ThyristorCenterTap2Pulse)110RMS supply voltage
SI.Frequencyf (from ThyristorCenterTap2Pulse)50Frequency
SI.AngleconstantFiringAngle30*pi/180Firing angle
SI.ResistanceR20Load resistance

Components

TypeNameDefaultDescription
Modelica.Electrical.Analog.Basic.Groundground (from ThyristorCenterTap2Pulse)
Modelica.Electrical.Analog.Sources.SineVoltagesinevoltage_n (from ThyristorCenterTap2Pulse)
Modelica.Electrical.Analog.Sources.SineVoltagesinevoltage_p (from ThyristorCenterTap2Pulse)
PowerConverters.ACDC.ThyristorCenterTap2Pulserectifier (from ThyristorCenterTap2Pulse)
Modelica.Electrical.Analog.Sensors.VoltageSensorvoltagesensor (from ThyristorCenterTap2Pulse)
Modelica.Blocks.Math.MeanmeanVoltage (from ThyristorCenterTap2Pulse)
Modelica.Blocks.Math.RootMeanSquarerootMeanSquareVoltage (from ThyristorCenterTap2Pulse)
Modelica.Electrical.Analog.Sensors.CurrentSensorcurrentSensor (from ThyristorCenterTap2Pulse)
Modelica.Blocks.Math.MeanmeanCurrent (from ThyristorCenterTap2Pulse)
PowerConverters.ACDC.Control.VoltageBridge2Pulsepulse2 (from ThyristorCenterTap2Pulse)
Modelica.Electrical.Analog.Basic.Resistorresistor