modelThyristorCenterTap2Pulse_RL

Two pulse thyristor rectifier with center tap and R-L load

Extends from ExampleTemplates.ThyristorCenterTap2Pulse (Template of two pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).

Information

This example shows a controlled center tap two pulse rectifier with R-L load.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Parameters

TypeNameDefaultDescription
SI.VoltageVrms (from ThyristorCenterTap2Pulse)110RMS supply voltage
SI.Frequencyf (from ThyristorCenterTap2Pulse)50Frequency
SI.AngleconstantFiringAngle30*pi/180Firing angle
SI.ResistanceR20Load resistance
SI.InductanceL1Load resistance

Components

TypeNameDefaultDescription
Modelica.Electrical.Analog.Basic.Groundground (from ThyristorCenterTap2Pulse)
Modelica.Electrical.Analog.Sources.SineVoltagesinevoltage_n (from ThyristorCenterTap2Pulse)
Modelica.Electrical.Analog.Sources.SineVoltagesinevoltage_p (from ThyristorCenterTap2Pulse)
PowerConverters.ACDC.ThyristorCenterTap2Pulserectifier (from ThyristorCenterTap2Pulse)
Modelica.Electrical.Analog.Sensors.VoltageSensorvoltagesensor (from ThyristorCenterTap2Pulse)
Modelica.Blocks.Math.MeanmeanVoltage (from ThyristorCenterTap2Pulse)
Modelica.Blocks.Math.RootMeanSquarerootMeanSquareVoltage (from ThyristorCenterTap2Pulse)
Modelica.Electrical.Analog.Sensors.CurrentSensorcurrentSensor (from ThyristorCenterTap2Pulse)
Modelica.Blocks.Math.MeanmeanCurrent (from ThyristorCenterTap2Pulse)
PowerConverters.ACDC.Control.VoltageBridge2Pulsepulse2 (from ThyristorCenterTap2Pulse)
Modelica.Electrical.Analog.Basic.Resistorresistor
Modelica.Electrical.Analog.Basic.Inductorinductor