modelThyristorCenterTap2Pulse_RLV
Two pulse thyristor rectifier with center tap and R-L load and voltage
Extends from ExampleTemplates.ThyristorCenterTap2Pulse (Template of two pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).
Information
This example shows a controlled center tap two pulse rectifier with R-L load including DC voltage source. The additional DC voltage source in this example enables negative average load voltages.
Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Voltage | Vrms (from ThyristorCenterTap2Pulse) | 110 | RMS supply voltage |
| SI.Frequency | f (from ThyristorCenterTap2Pulse) | 50 | Frequency |
| SI.Angle | constantFiringAngle | 30*pi/180 | Firing angle |
| SI.Resistance | R | 20 | Load resistance |
| SI.Inductance | L | 1 | Load resistance |
| SI.Voltage | VDC | -120 | DC load offset voltage |