modelThyristorCenterTap2Pulse_RLV_Characteristic
Characteristic of two pulse thyristor rectifier with center tap and R-L load and voltage
Extends from ExampleTemplates.ThyristorCenterTap2Pulse (Template of two pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).
Information
This example shows a controlled center tap two pulse rectifier with R-L load including DC voltage source. The additional DC voltage source in this example enables negative average load voltages.
Plot average voltage meanVoltage.v versus firingAngle pulse2.firingAngle to see control characteristic of this type of rectifier with R-L load including active voltage.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Voltage | Vrms (from ThyristorCenterTap2Pulse) | 110 | RMS supply voltage |
| SI.Frequency | f (from ThyristorCenterTap2Pulse) | 50 | Frequency |
| SI.Resistance | R | 20 | Load resistance |
| SI.Inductance | L | 1 | Load resistance |
| SI.Voltage | VDC | -120 | DC load offset voltage |