modelThyristorCenterTap2mPulse_RL

2*m pulse thyristor rectifier with R-L load

Extends from ExampleTemplates.ThyristorCenterTap2mPulse (Template of 2*m pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).

Information

This example shows a controlled 2*m pulse center tap rectifier with R-L load, where m is the number of phases.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Parameters

TypeNameDefaultDescription
Integerm (from ThyristorCenterTap2mPulse)3Number of phases
SI.VoltageVrms (from ThyristorCenterTap2mPulse)110RMS supply voltage
SI.Frequencyf (from ThyristorCenterTap2mPulse)50Frequency
SI.AngleconstantFiringAngle30*pi/180Firing angle
SI.ResistanceR20Load resistance
SI.InductanceL1Load resistance

Components

TypeNameDefaultDescription
Modelica.Electrical.Analog.Basic.Groundground (from ThyristorCenterTap2mPulse)
Modelica.Electrical.Polyphase.Basic.Starstar (from ThyristorCenterTap2mPulse)
Modelica.Electrical.Polyphase.Sources.SineVoltagesineVoltage_p (from ThyristorCenterTap2mPulse)
PowerConverters.ACDC.ThyristorCenterTap2mPulserectifier (from ThyristorCenterTap2mPulse)
Modelica.Electrical.Analog.Sensors.VoltageSensorvoltagesensor (from ThyristorCenterTap2mPulse)
Modelica.Blocks.Math.MeanmeanVoltage (from ThyristorCenterTap2mPulse)
Modelica.Blocks.Math.RootMeanSquarerootMeanSquareVoltage (from ThyristorCenterTap2mPulse)
Modelica.Electrical.Analog.Sensors.CurrentSensorcurrentSensor (from ThyristorCenterTap2mPulse)
Modelica.Blocks.Math.MeanmeanCurrent (from ThyristorCenterTap2mPulse)
PowerConverters.ACDC.Control.VoltageCenterTap2mPulsepulse2m (from ThyristorCenterTap2mPulse)
Modelica.Electrical.Polyphase.Sources.SineVoltagesineVoltage_n (from ThyristorCenterTap2mPulse)
Modelica.Electrical.Analog.Basic.Resistorresistor
Modelica.Electrical.Analog.Basic.Inductorinductor