modelThyristorCenterTap2mPulse_RLV_Characteristic
Characteristic of 2*m pulse center tap thyristor rectifier with R-L load and voltage
Extends from ExampleTemplates.ThyristorCenterTap2mPulse (Template of 2*m pulse thyristor rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).
Information
This example shows a controlled 2*m pulse center tap rectifier with R-L load including DC voltage source, where m is the number of phases. The additional DC voltage source in this example enables negative average load voltages.
Plot average voltage meanVoltage.v versus firingAngle pulsem.firingAngle to see control characteristic of this type of rectifier with R-L load including active voltage.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | m (from ThyristorCenterTap2mPulse) | 3 | Number of phases |
| SI.Voltage | Vrms (from ThyristorCenterTap2mPulse) | 110 | RMS supply voltage |
| SI.Frequency | f (from ThyristorCenterTap2mPulse) | 50 | Frequency |
| SI.Resistance | R | 20 | Load resistance |
| SI.Inductance | L | 1 | Load resistance |
| SI.Voltage | VDC | -260 | DC load offset voltage |