modelThyristorCenterTapmPulse_RLV
2*m pulse thyristor rectifier with center tap and R-L load and voltage
Extends from ExampleTemplates.ThyristorCenterTapmPulse (Template of 2*m pulse rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).
Information
This example shows a controlled m pulse center tap rectifier with R-L load including DC voltage source, where m is the number of phases. The additional DC voltage source in this example enables negative average load voltages.
Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | m (from ThyristorCenterTapmPulse) | 3 | Number of phases |
| SI.Voltage | Vrms (from ThyristorCenterTapmPulse) | 110 | RMS supply voltage |
| SI.Frequency | f (from ThyristorCenterTapmPulse) | 50 | Frequency |
| SI.Angle | constantFiringAngle | 30*pi/180 | Firing angle |
| SI.Resistance | R | 20 | Load resistance |
| SI.Inductance | L | 1 | Load resistance |
| SI.Voltage | VDC | -50 | DC load offset voltage |