modelThyristorCenterTapmPulse_RLV_Characteristic
Characteristic of 2*m pulse thyristor rectifier with center tap and R-L load and voltage
Extends from ExampleTemplates.ThyristorCenterTapmPulse (Template of 2*m pulse rectifier with center tap), Modelica.Icons.Example (Icon for runnable examples).
Information
This example shows a controlled m pulse center tap rectifier with R-L load including DC voltage source, where m is the number of phases. The additional DC voltage source in this example enables negative average load voltages.
Plot average voltage meanVoltage.v versus firingAngle pulsem.firingAngle to see control characteristic of this type of rectifier with R-L load including active voltage.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | m (from ThyristorCenterTapmPulse) | 3 | Number of phases |
| SI.Voltage | Vrms (from ThyristorCenterTapmPulse) | 110 | RMS supply voltage |
| SI.Frequency | f (from ThyristorCenterTapmPulse) | 50 | Frequency |
| SI.Resistance | R | 20 | Load resistance |
| SI.Inductance | L | 1 | Load resistance |
| SI.Voltage | VDC | -50 | DC load offset voltage |