functionkc_evenGapOverall

Mean heat transfer coefficient of even gap | overall flow regime | considering boundary layer development | heat transfer at ONE or BOTH sides | identical and constant wall temperatures | surface roughness

Extends from Modelica.Icons.Function (Icon for functions).

Information

Calculation of the mean convective heat transfer coefficient kc for an overall fluid flow through an even gap at different fluid flow and heat transfer situations. Note that additionally a failure status is observed in this function to check if the intended boundary conditions are fulfilled. See more information.

Inputs

TypeNameDefaultDescription
Modelica.Fluid.Dissipation.HeatTransfer.Channel.kc_evenGapOverall_IN_conIN_conInput record for function kc_evenGapOverall
Modelica.Fluid.Dissipation.HeatTransfer.Channel.kc_evenGapOverall_IN_varIN_varInput record for function kc_evenGapOverall

Outputs

TypeNameDefaultDescription
SI.CoefficientOfHeatTransferkcConvective heat transfer coefficient
SI.PrandtlNumberPrPrandtl number
SI.ReynoldsNumberReReynolds number
SI.NusseltNumberNuNusselt number
RealfailureStatus0== boundary conditions fulfilled | 1== failure >> check if still meaningful results

Contents

NameDescription
TYPprotected