recorddp_volumeFlowRate_IN_con
Input record for function dp_volumeFlowRate_DP and dp_volumeFlowRate_MFLOW
Extends from Modelica.Fluid.Dissipation.Utilities.Records.General.QuadraticVFLOW (Base record for generic pressure loss function | quadratic function (dp=a*Vdot^2 + b*Vdot)).
Information
This record is used as input record for the pressure loss function dp_volumeFlowRate_DP and dp_volumeFlowRate_MFLOW.Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | a (from QuadraticVFLOW) | 15 | Coefficient for quadratic term |
| Real | b (from QuadraticVFLOW) | 0 | Coefficient for linear term |
| SI.Pressure | dp_min | 0.1 | Start of approximation for decreasing pressure loss (only used for b=0) |