recordTjunction

Input for T-junction

Extends from Modelica.Icons.Record (Icon for records).

Components

TypeNameDefaultDescription
Booleanunited_converging_cross_sectiontrue= true, if A_cross_total = 2*A_cross_branch, otherwise A_cross_total > 2*A_cross_branch
Booleanvelocity_reference_branchestrue= true, if pressure loss coefficients w.r.t. velocity in each passage, otherwise w.r.t. velocity in total passage
Integeralpha90Angle of branching
SI.Diameter[3]d_hydones(3)*0.1Hydraulic diameter of passages [side,straight,total]
SI.MassFlowRatem_flow_min1e-3Restriction for smoothing at reverse fluid flow
SI.Velocityv_max2e2Restriction for maximum fluid flow velocity
Realzeta_TOT_max1e3Restriction for maximum value of pressure loss coefficient