functionpolynomialFlow

Polynomial flow characteristic, including linear extrapolation

Extends from baseFlow (Base class for pump flow characteristics).

Inputs

TypeNameDefaultDescription
SI.VolumeFlowRateV_flow (from baseFlow)Volumetric flow rate
SI.VolumeFlowRate[:]V_flow_nominalVolume flow rate for N operating points (single pump)
SI.Position[:]head_nominalPump head for N operating points

Outputs

TypeNameDefaultDescription
SI.Positionhead (from baseFlow)Pump head

Revisions

  • Jan 2013 by Rüdiger Franke:
    Extended with linear extrapolation outside specified points and reformulated polynomial evaluation