packageLaminar

Pipe wall friction for laminar flow in circular tubes (linear correlation)

Extends from PartialWallFriction (Partial wall friction characteristic (base package of all wall friction characteristics)).

Information

This component defines only the laminar region of wall friction: dp = k*m_flow, where "k" depends on density and dynamic viscosity. The roughness of the wall does not have an influence on the laminar flow and therefore argument roughness is ignored. Since this is a linear relationship, the occurring systems of equations are usually much simpler (e.g., either linear instead of non-linear). By using nominal values for density and dynamic viscosity, the systems of equations can still further be reduced.

In UsersGuide the complete friction regime is illustrated. This component describes only the Hagen-Poiseuille equation.


Parameters

TypeNameDefaultDescription
Booleanuse_mu (from PartialWallFriction)true= true, if mu_a/mu_b are used in function, otherwise value is not used
Booleanuse_roughness (from PartialWallFriction)true= true, if roughness is used in function, otherwise value is not used
Booleanuse_dp_small (from PartialWallFriction)true= true, if dp_small is used in function, otherwise value is not used
Booleanuse_m_flow_small (from PartialWallFriction)true= true, if m_flow_small is used in function, otherwise value is not used
Booleandp_is_zero (from PartialWallFriction)false= true, if no wall friction is present, i.e., dp = 0 (function massFlowRate_dp() cannot be used)
Booleanuse_Re_turbulent (from PartialWallFriction)true= true, if Re_turbulent input is used in function, otherwise value is not used

Contents

NameDescription
massFlowRate_dpReturn mass flow rate m_flow as function of pressure loss dp, i.e., m_flow = f(dp), due to wall friction
pressureLoss_m_flowReturn pressure loss dp as function of mass flow rate m_flow, i.e., dp = f(m_flow), due to wall friction
massFlowRate_dp_staticHeadReturn mass flow rate m_flow as function of pressure loss dp, i.e., m_flow = f(dp), due to wall friction and static head
pressureLoss_m_flow_staticHeadReturn pressure loss dp as function of mass flow rate m_flow, i.e., dp = f(m_flow), due to wall friction and static head