modelConstantReluctance

Constant reluctance

Extends from Interfaces.TwoPort (Interface component including flux balance equation), Modelica.Magnetic.FluxTubes.Icons.Reluctance (Icon for reluctance / permeance components).

Information

This constant reluctance is provided for test purposes and simple magnetic network models. The reluctance is not calculated from geometry and permeability of a flux tube, but is provided as parameter.

Parameters

TypeNameDefaultDescription
SI.ReluctanceR_m1Magnetic reluctance

Connectors

TypeNameDefaultDescription
FluxTubes.Interfaces.PositiveMagneticPortport_p (from TwoPortElementary)Positive magnetic port
FluxTubes.Interfaces.NegativeMagneticPortport_n (from TwoPortElementary)Negative magnetic port

Components

TypeNameDefaultDescription
SI.MagneticPotentialDifferenceV_m (from TwoPortExtended)Magnetic potential difference of ports
SI.MagneticFluxPhi (from TwoPortExtended)Magnetic flux from port_p to port_n