modelNewtonCoolingDynamic

Cooling example with fluctuating ambient conditions

Parameters

TypeNameDefaultDescription
TemperatureT0363.15Initial temperature
ConvectionCoefficienth0.7Convective cooling coefficient
AreaA1.0Surface area
Massm0.1Mass of thermal capacitance
SpecificHeatc_p1.2Specific heat

Components

TypeNameDefaultDescription
TemperatureT_infAmbient temperature
TemperatureTTemperature

Contents

NameDescription
Temperature
ConvectionCoefficient
Area
Mass
SpecificHeat