modelSplitter33

Splitter with three outlets

Information

Copyright © EDF 2002 - 2013

ThermoSysPro Version 3.1

This component model is documented in Sect. 14.8 of the ThermoSysPro book.

Parameters

TypeNameDefaultDescription
Integerfluid11: water/steam - 2: C3H3F5 - 3: Simple
Modelica.Units.SI.SpecificHeatCapacitycp4200Specific heat capacity
Integermode0IF97 region. 1:liquid - 2:steam - 4:saturation line - 0:automatic

Connectors

TypeNameDefaultDescription
ThermoSysPro.WaterSteam.Connectors.FluidInletCe
ThermoSysPro.WaterSteam.Connectors.FluidOutletCs3
ThermoSysPro.WaterSteam.Connectors.FluidOutletCs1
ThermoSysPro.WaterSteam.Connectors.FluidOutletCs2
ThermoSysPro.InstrumentationAndControl.Connectors.InputRealIalpha1Extraction coefficient for outlet 1 (<=1)
ThermoSysPro.InstrumentationAndControl.Connectors.InputRealIalpha2Extraction coefficient for outlet 2 (<=1)
ThermoSysPro.InstrumentationAndControl.Connectors.OutputRealOalpha1
ThermoSysPro.InstrumentationAndControl.Connectors.OutputRealOalpha2

Components

TypeNameDefaultDescription
Realalpha1Extraction coefficient for outlet 1 (<=1)
Realalpha2Extraction coefficient for outlet 2 (<=1)
Modelica.Units.SI.AbsolutePressurePFluid pressure
Modelica.Units.SI.SpecificEnthalpyhFluid specific enthalpy
Modelica.Units.SI.TemperatureTFluid temperature

Revisions

Authors

  • Baligh El Hefni
  • Daniel Bouskela