modelLumpedStraightPipe

Lumped straight pipe (circular duct)

Information

Copyright © EDF 2002 - 2019

ThermoSysPro Version 3.2

This component model is documented in Sect. 13.5 of the ThermoSysPro book.

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.LengthL10.Pipe length
Modelica.Units.SI.DiameterD0.2Pipe internal diameter
Integerntubes1Number of pipes in parallel
Reallambda0.03Friction pressure loss coefficient (active if lambda_fixed=true)
Realrugosrel0.0001Pipe roughness (active if lambda_fixed=false)
Modelica.Units.SI.Positionz10Inlet altitude
Modelica.Units.SI.Positionz20Outlet altitude
Booleanlambda_fixedtruetrue: lambda given by parameter - false: lambde computed using Idel'Cik correlation
Booleaninertiafalsetrue: momentum balance equation with inertia - false: without inertia
Booleancontinuous_flow_reversalfalsetrue: continuous flow reversal - false: discontinuous flow reversal
Integerfluid11: water/steam - 2: C3H3F5
Modelica.Units.SI.Densityp_rho0If > 0, fixed fluid density
Integermode0IF97 region. 1:liquid - 2:steam - 4:saturation line - 0:automatic

Connectors

TypeNameDefaultDescription
ThermoSysPro.WaterSteam.Connectors.FluidInletC1
ThermoSysPro.WaterSteam.Connectors.FluidOutletC2

Components

TypeNameDefaultDescription
RealkhiHydraulic pressure loss coefficient
ThermoSysPro.Units.SI.PressureDifferencedeltaPfFriction pressure loss
ThermoSysPro.Units.SI.PressureDifferencedeltaPTotal pressure loss
Modelica.Units.SI.MassFlowRateQMass flow rate
Modelica.Units.SI.ReynoldsNumberReReynolds number
Modelica.Units.SI.ReynoldsNumberRelimLimit Reynolds number
ReallamFriction pressure loss coefficient
Modelica.Units.SI.DensityrhoFluid density
Modelica.Units.SI.DynamicViscositymuFluid dynamic viscosity
Modelica.Units.SI.TemperatureTFluid temperature
Modelica.Units.SI.AbsolutePressurePmFluid average pressure
Modelica.Units.SI.SpecificEnthalpyhFluid specific enthalpy

Revisions

Authors

  • Daniel Bouskela
  • Baligh El Hefni