recordMachineData
Standard machine parameters
Extends from Modelica.Icons.Record (Icon for records).
Information
The machine parameter record contains all necessary parameters of a DC PM machine. It is used to parameterize the DCPM model, and it is used in the drive parameter record. Extending from this record, the parameters of other machines (with different parameters) can be saved.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Voltage | VANominal | 100 | Nominal armature voltage |
| Modelica.Units.SI.Current | IANominal | 100 | Nominal armature current |
| Modelica.Units.SI.AngularVelocity | wNominal | 1425*pi/30 | Nominal speed |
| Modelica.Units.SI.Resistance | RA | 0.05 | Armature resistance |
| Modelica.Units.SI.Inductance | LA | 0.0015 | Armature inductance |
| Modelica.Units.SI.Voltage | ViNominal | VANominal - RA*IANominal | Nominal induced voltage |
| Modelica.Units.SI.ElectricalTorqueConstant | kPhi | ViNominal/wNominal | Flux constant |
| Modelica.Units.SI.Inertia | J | 0.29 | Rotor inertia |
| Modelica.Units.SI.Torque | tauNominal | kPhi*IANominal | Nominal torque |