recordMachineData

Standard machine parameters

Extends from Modelica.Icons.Record (Icon for records).

Information

The machine parameter record contains all necessary parameters of a DC PM machine. It is used to parameterize the DCPM model, and it is used in the drive parameter record. Extending from this record, the parameters of other machines (with different parameters) can be saved.

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.VoltageVANominal100Nominal armature voltage
Modelica.Units.SI.CurrentIANominal100Nominal armature current
Modelica.Units.SI.AngularVelocitywNominal1425*pi/30Nominal speed
Modelica.Units.SI.ResistanceRA0.05Armature resistance
Modelica.Units.SI.InductanceLA0.0015Armature inductance
Modelica.Units.SI.VoltageViNominalVANominal - RA*IANominalNominal induced voltage
Modelica.Units.SI.ElectricalTorqueConstantkPhiViNominal/wNominalFlux constant
Modelica.Units.SI.InertiaJ0.29Rotor inertia
Modelica.Units.SI.TorquetauNominalkPhi*IANominalNominal torque