modelOrifice
Test cases of pressure loss functions for orifice
Extends from Modelica.Icons.Example (Icon for runnable examples).
Information
Switch to the diagram or equation layer to see the model of a Modelica.Fluid bend using Fluid.Dissipation pressure loss calculations .
This model executes pressure loss calculations out of the Fluid.Dissipation library for a bend of an incompressible and single-phase fluid flow considering surface roughness. Both the compressible case, where the mass flow rate (M_FLOW) is calculated in dependence of a known pressure loss (dp) and the incompressible case, where the pressure loss (DP) is calculated in dependence of a known mass flow rate (m_flow) are modelled.
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Fluid.System | system | ||
| Modelica.Blocks.Sources.Sine | input_mflow | ||
| Modelica.Blocks.Sources.RealExpression | input_p | ||
| Modelica.Fluid.Sources.Boundary_pT | IN_p | ||
| Modelica.Fluid.Sources.FixedBoundary | OUT_dp | ||
| Modelica.Fluid.Sources.FixedBoundary | OUT_mflow | ||
| Modelica.Fluid.Sources.MassFlowSource_T | IN_mflow | ||
| Modelica.Fluid.Fittings.Orifices.ThickEdgedOrifice | from_dp | Calculate mass flow rate from pressure loss | |
| Modelica.Fluid.Fittings.Orifices.ThickEdgedOrifice | from_mflow | Calculate pressure loss from mass flow rate |