modelTestWaterPumpCharacteristics

Test pump with default options and different selections of flowCharacteristic

Extends from Modelica.Icons.Example (Icon for runnable examples).

Information

The simulation results of two times two pumps being parameterized identically are compared.

The test includes extrapolation for heads ranging from about -10m to 110m, while the pump curves only cover 0m to 100m.

Components

TypeNameDefaultDescription
Modelica.Fluid.Sources.Boundary_pTSource
Modelica.Fluid.Sources.Boundary_pTSink
Modelica.Fluid.Machines.PrescribedPumppump
Modelica.Blocks.Sources.RampdownstreamPressure
Modelica.Fluid.Systemsystem
Modelica.Fluid.Machines.PrescribedPumppumpPolynomial
Modelica.Fluid.Machines.PrescribedPumppumpQuadraticLinearquadratic implementation for linear characteristics
Modelica.Fluid.Machines.PrescribedPumppumpLinear