modelSM_without_exciter
Information
Synchronous generator without exciter model.
Модель синхронного генератора с исключенным возбудителем.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| OMLET.Data.PQ_CapabilityTable | pq_table | OMLET.Data.TVV_500_2 | |
| Real | Qg | Reactive power, MVAR | |
| Real | Ignom | stator nomunal current, kA | |
| Real | PI | 4*atan(1) | PI-constant |
| Real | Wc | 2*PI*fbaz | frequency of electric current fluctuations |
| Real | Xt | 0.0 | resistance of step-up transformer and line to IB |
| Real | Ra | 0 | active resistance of generator stator winding |
| Real | Rt | 0 | active resistance of transformer |
| Real | EQ | Auxiliaire EMF of salient-pole generator | |
| Real | Dg | Generator power angle | |
| Real | Uq | D-axis ARV voltage reference value | |
| Real | Ud | Q-axis ARV voltage reference value | |
| Real | Id | D-axis stator current value | |
| Real | Iq | Q-axis stator current value | |
| Real | Eiq | synchronous stator EMF | |
| Real | Ir | field winding current | |
| Real | Uf | field winding voltage | |
| Real | Eq | EMF of generator | |
| Real | Er0 | EMF of generator initial value | |
| Real | PsiR | field winding flow coupling initial value | |
| Real | PsiRD | D-axis damper winding flow coupling initial value | |
| Real | PsiRQ | Q-axis damper winding flow coupling initial value | |
| Real | Mu0 | Turbine rotation moment initial value | |
| Real | Ut_pu | stator voltage, p.u. | |
| Real | Pg_pu | Active power, p.u. | |
| Real | Qg_pu | Reactive power, p.u. | |
| General | |||
| Boolean | inService_G | true | Generator topological condition |
| Real | TgenOff | 1000 | Time of generator's disconnection, s |
| Real | dTgenOff | 10 | Duration of generator's disconnection, s |
| Real | Sbaz | sysData.Sbaz | Bazic power, MWA |
| Real | fbaz | sysData.fbaz | Bazic frequency, Hz |
| Real | Pg | 500 | Active power, MW |
| Real | Ut | 20 | ARV voltage reference value, kV |
| Real | Pnom | 500 | Nominal maschine active power, MW |
| Real | Ugnom | 20 | Nominal stator voltage, kV |
| Real | cosfi_nom | 0.85 | Nominal maschine power coefficient, p.u. |
| Real | TkzOn | 1000 | Generators dropping on-time, s |
| Real | Pg_new | 100 | New power of power plant, MW |
| Synchronous machine | |||
| Real | Kd | 0 | damping coefficient |
| Real | Xd_p | 1.869 | D-axis synchronous reactance, p.u. |
| Real | Xq_p | 1.869 | Q-axis synchronous reactance, p.u. |
| Real | Xs_p | 0.194 | Leakage reactance of stator winding, p.u. |
| Real | X1d_p | 0.3016 | D-axis transient reactance, p.u. |
| Real | X2d_p | 0.2337 | D-axis subtransient reactance, p.u. |
| Real | X2q_p | 0.2337 | Q-axis subtransient reactance, p.u. |
| Real | Tj_p | 7 | Inertia coefficient, s |
| Real | Td0 | 10 | D-axis transient time constant, s |
| Real | T2d_p | 0.02 | D-axis subtransient time constant, s |
| Real | T2q_p | 0.05 | Q-axis subtransient time constant, s |
| Turbine | |||
| Real | TregOff | 50 | Turbine speed regulator off-time, s |
| Real | Mtmax | 1.1 | Turbine overloading coefficient, p.u. |
| Real | Mtmin | 0 | Turbine minimum-loading coefficient, p.u. |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| OMLET.Interfaces.Pin_v2 | Stator_pin | ||
| OMLET.Interfaces.Signal_pin | Ef_pin | ||
| OMLET.Interfaces.Signal_pin | dUtr_pin | ||
| OMLET.Interfaces.Signal_pin | dWu_pin | ||
| OMLET.Interfaces.Signal_pin | dWf_pin | ||
| OMLET.Interfaces.Signal_pin | dIf_pin | ||
| OMLET.Interfaces.Signal_pin | Ut_pin | ||
| Interfaces.Signal_pin | Er0_pin | ||
| Interfaces.Signal_pin | Ugen_pin | ||
| Interfaces.Signal_pin | dIg_pin | ||
| Interfaces.Signal_pin | slip_pin | ||
| Interfaces.Signal_pin | Mu0_pin | ||
| Interfaces.Signal_pin | Mt_pin |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| SysData | sysData | ||
| Real | Qmax | Current limit of overexcitation, MVar | |
| Real | Qmin | Current limit of underexcitation, MVar | |
| Real | P_clipped_max | Sliced P for Qmax interpolation | |
| Real | P_clipped_min | Sliced P for Qmin interpolation | |
| Integer | i_max_dummy | ||
| Integer | i_min_dummy | ||
| Real | Rf_p | Active resistance of field winding, p.u. | |
| Real | R1d_p | Active resistance of d-axis damper winding, p.u. | |
| Real | R1q_p | Active resistance of q-axis damper winding, p.u. | |
| Real | dUtr | voltage deviation | |
| Real | dWu | frequency deviation | |
| Real | dIf | current deviation | |
| Real | dWf | frequency deviation | |
| Real | Er | exciter electromotive force | |
| Real | Uf_full | field winding voltage actual value | |
| Real | Xad | D-axis resistance to mutual induction | |
| Real | Xaq | Q-axis resistance to mutual induction | |
| Real | X2dt | D-axis subtransient reactance of generator and transformer | |
| Real | X2qt | Q-axis subtransient reactance of generator and transformer | |
| Real | Rs | Sum resistance of stator winding and step-up transformer | |
| Real | Xsf | Leakage reactance of field winding | |
| Real | Xs1d | D-axis leakage reactance of damping winding | |
| Real | Xs1q | Q-axis leakage reactance of damping winding | |
| Real | X1 | interim reactance в„–1 | |
| Real | X2 | interim reactance в„–2 | |
| Real | X3 | interim reactance в„–3 | |
| Real | Ugen | generator full voltage actual value, kV | |
| Real | Igen | generator stator current value, kA | |
| Real | Mt_pp | Turbine rotation moment actual value | |
| Real | Pgen | Generator active power actual value | |
| Real | Qgen | Generator reactive power actual value | |
| Real | UdG | ||
| Real | UqG | ||
| Real | IdG | ||
| Real | IqG | ||
| Real | DeltaIJ | ||
| Real | Ssys | system slip | |
| Real | Yr | field winding flow coupling actual value | |
| Real | Yrd | D-axis damper winding flow coupling actual value | |
| Real | Yrq | Q-axis damper winding flow coupling actual value | |
| Real | s | generator slip | |
| Real | DGi | Generator power angle initial value | |
| Real | Me | electrical moment | |
| Real | Yad | D-axis flow coupling of mutual inductance | |
| Real | Yaq | Q-axis flow coupling of mutual inductance | |
| Real | iq | Q-axis generator stator winding current actual value | |
| Real | id | D-axis generator stator winding current actual value | |
| Real | ir | D-axis generator field winding current actual value | |
| Real | ird | D-axis generator damper winding current actual value | |
| Real | irq | Q-axis generator damper winding current actual value | |
| Real | ud | D-axis generator voltage actual value | |
| Real | uq | Q-axis generator voltage actual value | |
| Real | E11d | EMF, connected with d-axis damper winding | |
| Real | E11q | EMF, connected with q-axis damper winding | |
| Real | MT_MAX | Turbine overloading coefficient actual value | |
| Real | MT_MIN | Turbine minimum-loading coefficient actual value | |
| Real | Xd | D-axis synchronous reactance actual value | |
| Real | Xq | Q-axis synchronous reactance actual value | |
| Real | Xs | Leakage reactance actual value | |
| Real | X1d | D-axis transient reactance actual value | |
| Real | X2d | D-axis subtransient reactance actual value | |
| Real | X2q | Q-axis subtransient reactance actual value | |
| Real | Rf | Active resistance of field winding actual value | |
| Real | R1d | Active resistance of d-axis damper winding actual value | |
| Real | R1q | Active resistance of q-axis damper winding actual value | |
| Real | Tj | Inertia coefficient actual value | |
| Real | f | frequency |