modelPumpTest

AccuTest

Extends from OpenHydraulics.Interfaces.PartialFluidCircuit (Base model for any component involving fluid).

Parameters

TypeNameDefaultDescription
RealdispFraction1
RealCv60000Coefficient of viscous drag
RealCf0.007Coefficient of Coulomb friction (fraction of full stroke torque)
RealCs1.8e-9Leakage coefficient
RealVr0.54Volume ratio of pump or motor
SI.DynamicViscositymuoil.dynamicViscosity(5e6)Dynamic viscosity (used only for efficiency models)
SI.BulkModulusBoil.approxBulkModulus(5e6)Approximate bulk modulus (used only for efficiency models)

Components

TypeNameDefaultDescription
OpenHydraulics.Fluids.GenericOilSimpleoil (from PartialFluidCircuit)Oil model
OpenHydraulics.Circuits.Environmentenvironment (from PartialFluidCircuit)
RealvolumetricEfficiency2500
RealmechanicalEfficiency2500
RealenergyEfficiency2500
RealvolumetricEfficiency5000
RealmechanicalEfficiency5000
RealenergyEfficiency5000
OpenHydraulics.Components.MotorsPumps.VariableDisplacementPumpvariableDisplacementPump
Basic.ConstPressureSourcelowPressure
Basic.ConstPressureSourcehighPressure
Modelica.Blocks.Sources.RealExpressionrealExpression
OpenHydraulics.Components.MotorsPumps.VariableDisplacementPumpvariableDisplacementPump1
Basic.ConstPressureSourcelowPressure1
Basic.ConstPressureSourcehighPressure1
Modelica.Mechanics.Rotational.Sources.ConstantSpeedconstantSpeed