The example MultiDomainTypeI contains a multi-domain three-phase type I induction motor model which drives a mechanical load. The three-phase induction motor type I is based on the non multi-domain model from Milano, Federico. Power system modelling and scripting. Springer Science & Business Media, 2010.
In order to validate the multi-domain model, this validation example reproduces Example 11.7 Motor Startup from Chow, Joe H., and Juan J. Sanchez-Gasca. Power system modeling, computation, and control. John Wiley & Sons, 2020.
The startup example from the book utilizes a three-phase type III induction motor . In this particular Modelica validation example, the idea is to test the more simple model type I to compare results.
Simulate the system for 10 seconds. Variables of interest are:
Motor1.s
Motor1.wr
Motor1.P
Motor1.Q
Motor1.Pmotor