.OpenIPSL.Electrical.ThreePhase.Loads.WyeLoad_1Ph

Information

This is a single-phase load model.

The user needs to input the active (P_a) and reactive (Q_a) powers consumed by the phase. Since the values come from independent parameters, the model allows the representation of unbalanced loads.

In addition, the model allows the load to be represented as constant power, or as a ZIP model. In the first approach, the load consumes the same value of active and reactive powers throughout the simulation. The latter approach allows the load to be represented as a sum of three terms: constant impedance, constant current and constant power. This means that, depending on voltage levels supplied, the load will consume different values of power.


Generated at 2024-12-11T19:25:49Z by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos