blockSimpleLagRateLimVar
First order lag transfer function block with a non windup limiter, rate limits, variable output limits and blocking input
Extends from Modelica.Blocks.Interfaces.SISO (Single Input Single Output continuous control block).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Types.Time | T | Lag time constant | |
| Real | rmin | Minimum rate limit | |
| Real | rmax | Maximum rate limit | |
| Initialization | |||
| Real | y_start | Output start value | |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| RealInput | u (from SISO) | Connector of Real input signal | |
| RealOutput | y (from SISO) | Connector of Real output signal | |
| Modelica.Blocks.Interfaces.RealInput | outMin | ||
| Modelica.Blocks.Interfaces.RealInput | outMax |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | rate | Rate | |
| Real | x |