modelCSVGN1

SMIB system to test functionality of model CSVGN1

Extends from OpenIPSL.Tests.BaseClasses.SMIB (SMIB - Single Machine Infinite Base system with one load.).

Information

The CSVGN is a Static Compensator and should inject reactive power to control the terminal bus voltage during the fault disturbance. Simulate for 10 seconds.

Variables of interest:

  • cSVGN1.v
  • cSVGN1.Q

Components

TypeNameDefaultDescription
OpenIPSL.Electrical.Branches.PwLinepwLine (from SMIB)
OpenIPSL.Electrical.Branches.PwLinepwLine3 (from SMIB)
OpenIPSL.Electrical.Branches.PwLinepwLine4 (from SMIB)
OpenIPSL.Electrical.Machines.PSSE.GENCLSgENCLS (from SMIB)
OpenIPSL.Electrical.Loads.PSSE.Load_variationconstantLoad (from SMIB)
OpenIPSL.Electrical.Events.PwFaultpwFault (from SMIB)
OpenIPSL.Electrical.Buses.BusGEN1 (from SMIB)
OpenIPSL.Electrical.SystemBaseSysData (from SMIB)
OpenIPSL.Electrical.Buses.BusLOAD (from SMIB)
OpenIPSL.Electrical.Buses.BusGEN2 (from SMIB)
OpenIPSL.Electrical.Buses.BusFAULT (from SMIB)
Electrical.Branches.PwLinepwLine1 (from SMIB)
Electrical.Branches.PwLinepwLine2 (from SMIB)
Electrical.Buses.BusSHUNT (from SMIB)
OpenIPSL.Electrical.Machines.PSSE.GENSALgENSAL
OpenIPSL.Electrical.Banks.PSSE.CSVGN1cSVGN1
Modelica.Blocks.Sources.RealExpressionrealExpression
Modelica.Blocks.Sources.Constantconst